<Emissions xsi:noNamespaceSchemaLocation="C:\Program Files\ECMPS\XML\Emissions.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
   <ORISCode>880102</ORISCode>
   <Year>2024</Year>
   <Quarter>2</Quarter>
   <SubmissionComment/>
   <Version>1.8</Version>
   <SummaryValueData>
      <UnitID>1</UnitID>
      <ParameterCode>OPHOURS</ParameterCode>
      <CurrentReportingPeriodTotal>1083.000</CurrentReportingPeriodTotal>
      <OzoneSeasonToDateTotal/>
      <YearToDateTotal>2990.000</YearToDateTotal>
   </SummaryValueData>
   <SummaryValueData>
      <UnitID>1</UnitID>
      <ParameterCode>OPTIME</ParameterCode>
      <CurrentReportingPeriodTotal>1078.800</CurrentReportingPeriodTotal>
      <OzoneSeasonToDateTotal/>
      <YearToDateTotal>2977.750</YearToDateTotal>
   </SummaryValueData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-01</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-01</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.400</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>9</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-01</ZeroInjectionDate>
         <ZeroInjectionHour>9</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-01</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC199420</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-02</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-02</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.500</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.100</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>9</Hour>
      <Minute>13</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-02</ZeroInjectionDate>
         <ZeroInjectionHour>9</ZeroInjectionHour>
         <ZeroInjectionMinute>5</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-02</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>13</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC199420</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-03</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-03</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>9</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-03</ZeroInjectionDate>
         <ZeroInjectionHour>9</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-03</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC199420</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-04</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-04</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.500</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.800</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>9</Hour>
      <Minute>3</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-04</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>55</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-04</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>3</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC199420</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-05</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-05</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.500</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.700</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>9</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-05</ZeroInjectionDate>
         <ZeroInjectionHour>9</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-05</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC199420</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-06</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-06</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.500</ZeroMeasuredValue>
         <UpscaleMeasuredValue>526.000</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>9</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-06</ZeroInjectionDate>
         <ZeroInjectionHour>9</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-06</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC199420</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-07</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-07</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.400</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>9</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-07</ZeroInjectionDate>
         <ZeroInjectionHour>9</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-07</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC199420</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-08</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-08</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.600</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.300</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>9</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-08</ZeroInjectionDate>
         <ZeroInjectionHour>9</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-08</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-09</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-09</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.100</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>9</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-09</ZeroInjectionDate>
         <ZeroInjectionHour>9</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-09</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.300</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>8</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-10</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-10</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>8</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>9</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-10</ZeroInjectionDate>
         <ZeroInjectionHour>9</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-10</UpscaleInjectionDate>
         <UpscaleInjectionHour>9</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-11</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-11</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.900</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.900</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-11</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-11</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-12</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-12</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.800</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-12</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-12</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-13</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-13</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-13</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-13</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-14</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-14</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.300</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-14</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-14</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-15</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-15</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>1.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.100</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-15</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-15</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-16</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-16</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.800</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.700</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-16</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-16</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-17</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-17</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.300</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-17</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-17</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-18</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-18</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.900</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-18</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-18</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-19</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-19</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-19</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-19</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-20</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-20</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.600</ZeroMeasuredValue>
         <UpscaleMeasuredValue>526.000</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-20</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-20</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-21</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-21</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-21</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-21</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-22</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-22</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>526.200</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-22</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-22</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-23</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-23</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.000</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-23</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-23</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-24</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-24</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.400</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-24</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-24</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-25</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-25</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-25</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-25</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-26</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-26</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.400</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.000</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-26</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-26</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-27</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-27</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.500</ZeroMeasuredValue>
         <UpscaleMeasuredValue>526.300</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-27</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-27</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-28</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-28</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.700</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-28</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-28</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-29</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-29</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-29</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-29</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.20</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-30</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-30</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-04-30</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-04-30</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>9</Hour>
      <Minute>41</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-01</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-01</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.800</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.900</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-01</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-01</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.20</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-02</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-02</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.500</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.800</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-02</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-02</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.800</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.30</ZeroCalibrationError>
         <UpscaleCalibrationError>0.40</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-03</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-03</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-03</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-03</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.800</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.30</ZeroCalibrationError>
         <UpscaleCalibrationError>0.40</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-04</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-04</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>1.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.300</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-04</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-04</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.700</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.30</ZeroCalibrationError>
         <UpscaleCalibrationError>0.30</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-05</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-05</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.400</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-05</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-05</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-06</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-06</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>526.700</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-06</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-06</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-07</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-07</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-07</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-07</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.700</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.30</ZeroCalibrationError>
         <UpscaleCalibrationError>0.30</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-08</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-08</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.300</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-08</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-08</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.700</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.30</ZeroCalibrationError>
         <UpscaleCalibrationError>0.30</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-09</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-09</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.700</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-05-09</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-05-09</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.20</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.400</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>CC308961</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-25</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-25</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.600</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-25</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-25</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.300</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>DT0017362</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>10</Hour>
      <Minute>55</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-26</ZeroInjectionDate>
         <ZeroInjectionHour>10</ZeroInjectionHour>
         <ZeroInjectionMinute>51</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-26</UpscaleInjectionDate>
         <UpscaleInjectionHour>10</UpscaleInjectionHour>
         <UpscaleInjectionMinute>55</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.200</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.200</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>10</Hour>
      <Minute>56</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>11</Hour>
      <Minute>49</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-26</ZeroInjectionDate>
         <ZeroInjectionHour>11</ZeroInjectionHour>
         <ZeroInjectionMinute>41</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-26</UpscaleInjectionDate>
         <UpscaleInjectionHour>11</UpscaleInjectionHour>
         <UpscaleInjectionMinute>49</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.300</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>DT0017362</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-27</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-27</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.700</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-27</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-27</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.300</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>DT0017362</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-28</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-28</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.400</ZeroMeasuredValue>
         <UpscaleMeasuredValue>525.200</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-28</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-28</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.300</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>DT0017362</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-29</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-29</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.300</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.800</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-29</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-29</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.000</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.400</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.10</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.300</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>DT0017362</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>7</Hour>
      <Minute>29</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>HIGH</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-30</ZeroInjectionDate>
         <ZeroInjectionHour>7</ZeroInjectionHour>
         <ZeroInjectionMinute>25</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-30</UpscaleInjectionDate>
         <UpscaleInjectionHour>7</UpscaleInjectionHour>
         <UpscaleInjectionMinute>29</UpscaleInjectionMinute>
         <ZeroMeasuredValue>-0.400</ZeroMeasuredValue>
         <UpscaleMeasuredValue>524.800</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.00</ZeroCalibrationError>
         <UpscaleCalibrationError>0.00</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>525.000</UpscaleReferenceValue>
         <UpscaleGasTypeCode/>
         <CylinderIdentifier/>
         <VendorIdentifier/>
         <ExpirationDate/>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>7</Hour>
      <Minute>30</Minute>
      <MonitoringSystemID/>
      <ComponentID>104</ComponentID>
      <TestTypeCode>INTCHK</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode/>
   </DailyTestSummaryData>
   <DailyTestSummaryData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>8</Hour>
      <Minute>23</Minute>
      <MonitoringSystemID/>
      <ComponentID>105</ComponentID>
      <TestTypeCode>DAYCAL</TestTypeCode>
      <TestResultCode>PASSED</TestResultCode>
      <SpanScaleCode>H</SpanScaleCode>
      <DailyCalibrationData>
         <OnLineOffLineIndicator>1</OnLineOffLineIndicator>
         <UpscaleGasCode>MID</UpscaleGasCode>
         <ZeroInjectionDate>2024-06-30</ZeroInjectionDate>
         <ZeroInjectionHour>8</ZeroInjectionHour>
         <ZeroInjectionMinute>15</ZeroInjectionMinute>
         <UpscaleInjectionDate>2024-06-30</UpscaleInjectionDate>
         <UpscaleInjectionHour>8</UpscaleInjectionHour>
         <UpscaleInjectionMinute>23</UpscaleInjectionMinute>
         <ZeroMeasuredValue>0.100</ZeroMeasuredValue>
         <UpscaleMeasuredValue>11.500</UpscaleMeasuredValue>
         <ZeroAPSIndicator>0</ZeroAPSIndicator>
         <UpscaleAPSIndicator>0</UpscaleAPSIndicator>
         <ZeroCalibrationError>0.10</ZeroCalibrationError>
         <UpscaleCalibrationError>0.20</UpscaleCalibrationError>
         <ZeroReferenceValue>0.000</ZeroReferenceValue>
         <UpscaleReferenceValue>11.300</UpscaleReferenceValue>
         <UpscaleGasTypeCode>BALN,O2</UpscaleGasTypeCode>
         <CylinderIdentifier>DT0017362</CylinderIdentifier>
         <VendorIdentifier>F12021</VendorIdentifier>
         <ExpirationDate>2029-11-18</ExpirationDate>
         <InjectionProtocolCode/>
      </DailyCalibrationData>
   </DailyTestSummaryData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>157</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>46389000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>46389000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>157</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>46139000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>46139000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>158</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>46398000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>46398000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>46794000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>46794000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>47290000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>47290000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>47229000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>47229000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>47260000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>47260000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>47134000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>47134000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48502000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48502000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49138000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49138000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>44961000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>44961000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>156</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42075000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42075000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42053000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42053000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>154</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33865000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33865000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>151</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29432000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29432000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>151</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30493000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30493000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>151</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31019000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31019000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30061000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30061000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>164</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32070000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32070000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30455000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30455000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27811000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27811000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28270000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28270000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28134000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28134000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-01</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>164</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30666000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30666000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28273000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28273000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27795000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27795000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27587000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27587000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27525000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27525000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27442000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27442000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>157</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28379000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28379000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>152</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29894000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29894000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>152</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29473000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29473000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>152</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29600000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29600000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>152</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29668000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29668000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34355000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34355000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34092000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34092000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34217000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34217000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34042000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34042000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30522000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30522000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29990000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29990000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30431000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30431000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29936000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29936000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29202000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29202000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29606000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29606000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27632000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27632000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27595000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27595000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27571000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27571000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-02</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27671000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27671000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27563000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27563000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27771000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27771000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27708000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27708000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27615000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27615000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27909000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27909000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28170000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28170000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28591000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28591000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28112000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28112000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28091000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28091000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27980000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27980000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27981000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27981000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28327000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28327000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28206000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28206000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28096000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28096000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28139000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28139000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29623000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29623000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>152</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30271000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30271000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>167</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32409000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32409000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>178</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33107000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33107000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>185</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31876000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31876000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>190</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33295000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33295000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>196</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34484000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34484000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>201</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37352000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37352000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-03</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>206</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38060000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38060000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38699000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38699000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39159000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39159000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>217</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40607000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40607000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41499000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41499000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41696000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41696000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41606000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41606000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41501000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41501000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41702000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41702000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41339000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41339000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>86.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>229</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41334000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41334000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.95E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>231</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41452000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41452000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>234</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41577000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41577000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.91E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>235</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41499000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41499000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.91E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>235</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41583000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41583000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.91E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>236</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41993000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41993000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.91E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>236</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41708000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41708000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.91E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>238</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>10</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41590000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41590000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.91E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>236</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41441000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41441000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.91E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40566000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40566000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>231</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40956000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40956000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41220000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41220000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40870000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40870000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40719000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40719000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-04</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40730000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40730000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41008000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41008000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41240000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41240000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41158000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41158000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41306000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41306000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.61</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41354000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41354000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41356000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41356000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41472000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41472000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41663000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41663000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41201000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41201000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41054000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41054000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>6.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.89E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40932000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40932000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>6.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.89E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41756000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41756000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41941000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41941000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41849000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41849000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41884000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41884000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41779000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41779000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41880000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41880000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42053000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42053000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41774000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41774000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41269000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41269000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.92E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41502000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41502000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41908000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41908000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.95E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41775000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41775000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.97E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-05</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41853000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41853000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.97E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41931000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41931000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.97E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41915000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41915000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.98E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42161000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42161000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.98E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42235000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42235000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.98E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42168000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42168000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.98E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42250000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42250000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.97E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42365000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42365000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.97E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42353000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42353000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.95E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42347000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42347000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>207</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42181000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42181000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.16E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>217</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42236000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42236000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.09E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>224</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42802000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42802000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.06E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43125000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43125000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.03E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>312.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>312.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43078000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43078000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.03E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>312.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>311.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42329000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42329000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.98E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41845000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41845000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.97E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42519000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42519000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.99E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42128000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42128000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.98E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41425000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41425000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.97E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>221</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40377000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40377000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.99E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>222</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40617000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40617000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.98E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41512000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41512000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.95E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41586000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41586000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.95E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-06</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41439000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41439000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.95E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41377000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41377000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.95E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41394000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41394000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.95E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41441000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41441000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.97E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>226</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40825000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40825000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.99E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>201</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37995000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37995000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.16E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>180</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>35219000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>35219000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>255.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>256.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>168</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33876000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33876000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>245.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>245.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32174000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32174000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.37E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>232.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>233.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31635000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31635000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>229.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>228.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31471000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31471000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.31E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>228.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>228.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31448000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31448000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.31E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>227.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>226.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31609000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31609000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.31E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>228.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>228.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31662000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31662000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.31E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>229.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>228.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32277000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32277000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.27E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>233.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>232.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>179</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34778000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34778000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>250.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>250.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>199</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38640000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38640000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.09E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>278.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>279.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>214</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41039000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41039000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.06E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41257000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41257000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.03E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41030000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41030000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41870000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41870000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>229</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42467000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42467000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.99E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42663000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42663000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.99E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42789000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42789000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.99E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-07</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42766000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42766000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.99E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42662000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42662000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42833000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42833000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42851000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42851000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42709000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42709000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42579000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42579000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42558000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42558000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42429000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42429000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42431000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42431000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.99E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42945000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42945000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.08E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>283.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>15.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>318.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42704000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42704000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>194.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>21.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>313.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42113000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42113000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.16E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42083000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42083000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41997000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41997000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.11</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42039000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42039000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42124000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42124000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42207000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42207000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42308000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42308000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42598000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42598000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42654000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42654000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42713000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42713000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42412000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42412000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42517000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42517000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39735000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39735000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.31E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>282.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>282.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-08</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41114000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41114000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>226</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41720000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41720000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42327000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42327000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42276000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42276000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42177000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42177000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42257000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42257000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38904000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38904000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>278.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>277.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>201</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37384000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37384000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.28E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>265.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>266.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>200</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37436000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37436000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>266.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>266.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>200</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37148000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37148000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>263.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>264.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>178</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33936000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33936000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.45E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>241.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>241.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>161</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32822000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32822000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>232.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>233.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32315000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32315000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.49E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>230.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>229.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32133000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32133000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.51E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>228.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>227.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>145</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31417000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31417000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.53E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>223.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>222.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>145</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31275000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31275000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.53E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>222.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>146</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31173000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31173000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>145</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31454000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31454000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>223.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>224.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>145</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31539000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31539000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>223.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>224.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>147</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31540000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31540000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>223.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>224.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>168</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33363000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33363000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.49E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>236.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>235.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>197</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37638000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37638000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>266.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>266.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40592000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40592000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41200000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41200000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-09</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41093000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41093000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>291.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39119000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39119000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>279.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>279.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>190</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36371000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36371000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>188</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37584000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37584000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>266.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>266.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>208</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39898000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39898000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.33E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>283.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>283.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>221</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41278000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41278000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41092000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41092000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41270000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41270000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41171000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41171000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41049000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41049000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>291.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41260000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41260000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40996000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40996000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>291.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40870000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40870000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41097000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41097000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41038000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41038000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>291.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41517000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41517000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41753000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41753000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41572000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41572000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41685000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41685000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41957000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41957000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42181000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42181000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42202000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42202000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42111000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42111000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42279000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42279000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-10</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42247000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42247000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42202000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42202000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42402000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42402000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42274000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42274000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42231000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42231000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42017000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42017000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42076000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42076000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41973000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41973000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41863000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41863000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41805000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41805000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>284.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>291.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>229</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41838000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41838000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>208.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>20.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>320.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>222</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40637000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40637000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41518000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41518000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42453000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42453000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42307000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42307000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42313000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42313000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42599000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42599000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>311.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>311.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42709000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42709000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>312.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>311.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42655000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42655000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>312.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>311.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42357000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42357000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42015000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42015000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42091000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42091000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42154000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42154000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42260000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42260000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.61</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-11</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42018000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42018000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42194000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42194000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42130000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42130000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42102000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42102000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42149000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42149000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>229</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41885000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41885000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41836000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41836000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42019000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42019000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42198000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42198000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41291000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41291000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>214</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39480000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39480000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40692000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40692000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40709000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40709000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40659000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40659000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40540000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40540000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40616000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40616000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41545000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41545000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42442000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42442000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42475000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42475000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42718000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42718000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>312.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>312.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42914000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42914000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.39E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>313.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>313.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42558000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42558000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>311.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>311.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42582000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42582000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42464000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42464000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-12</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42502000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42502000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42552000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42552000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42388000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42388000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42303000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42303000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42305000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42305000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42330000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42330000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42491000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42491000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42402000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42402000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42279000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42279000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42126000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42126000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>229</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41989000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41989000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>221</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40680000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40680000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40938000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40938000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40952000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40952000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40882000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40882000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41401000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41401000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41622000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41622000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41677000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41677000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42238000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42238000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42239000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42239000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41935000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41935000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40348000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40348000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41158000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41158000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>229</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41256000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41256000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-13</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>231</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41613000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41613000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41850000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41850000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41118000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41118000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41362000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41362000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41280000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41280000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41081000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41081000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41169000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41169000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41446000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41446000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41300000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41300000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40807000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40807000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.17E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40772000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40772000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.17E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40844000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40844000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.17E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41052000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41052000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.17E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41072000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41072000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.17E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41252000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41252000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.20E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41404000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41404000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41241000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41241000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.20E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41337000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41337000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41491000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41491000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41437000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41437000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41239000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41239000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.20E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41116000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41116000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41694000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41694000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42063000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42063000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-14</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42233000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42233000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.61</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42256000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42256000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42230000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42230000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42015000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42015000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41963000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41963000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42119000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42119000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41929000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41929000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42419000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42419000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42281000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42281000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.32E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42524000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42524000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>4.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>4.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42067000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42067000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.54E-1</UnadjustedHourlyValue>
         <MODCCode>41</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.23E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>T</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>217.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>19.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>T</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>328.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41921000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41921000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.42E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42054000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42054000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.42E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42245000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42245000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42502000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42502000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.61</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42590000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42590000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42568000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42568000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42739000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42739000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42477000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42477000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42413000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42413000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42470000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42470000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42456000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42456000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42782000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42782000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42955000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42955000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-15</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43021000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43021000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43181000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43181000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43144000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43144000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>231</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42679000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42679000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42665000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42665000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43033000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43033000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43265000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43265000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43104000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43104000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42859000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42859000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42581000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42581000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42467000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42467000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.42E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42298000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42298000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.42E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42110000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42110000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42274000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42274000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42300000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42300000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.11</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42394000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42394000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42410000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42410000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42300000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42300000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42634000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42634000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42843000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42843000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>224</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42971000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42971000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.72E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>218</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43144000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43144000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.86E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>218</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42999000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42999000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.86E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>221</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43341000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43341000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.86E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-16</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>222</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43218000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43218000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.86E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>222</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43165000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43165000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.86E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>224</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43203000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43203000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.81E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42837000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42837000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42860000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42860000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42908000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42908000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42819000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42819000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42653000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42653000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42720000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42720000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42482000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42482000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42234000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42234000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42257000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42257000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.42E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>230</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42511000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42511000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.46E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42343000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42343000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>226</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42097000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42097000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>226</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42379000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42379000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>226</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42148000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42148000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>226</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41909000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41909000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42256000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42256000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42499000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42499000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42981000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42981000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.68E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42736000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42736000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42648000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42648000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42692000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42692000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-17</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42653000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42653000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42599000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42599000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42558000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42558000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42513000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42513000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42302000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42302000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42362000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42362000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42317000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42317000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42307000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42307000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42288000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42288000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42172000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42172000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.74E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>324.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41784000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41784000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.10E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>94.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>44.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>204.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>20.4</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41864000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41864000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.10E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.11</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42056000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42056000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.10E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42176000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42176000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.10E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42375000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42375000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.14E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42473000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42473000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.14E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42576000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42576000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42994000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42994000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42582000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42582000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42449000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42449000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42572000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42572000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42349000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42349000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42475000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42475000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42269000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42269000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-18</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>227</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42304000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42304000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41846000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41846000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41852000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41852000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41306000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41306000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41274000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41274000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42068000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42068000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42155000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42155000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42512000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42512000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42568000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42568000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>216</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40622000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40622000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>291.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>221</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41602000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41602000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42239000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42239000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42650000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42650000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42636000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42636000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42635000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42635000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42669000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42669000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.34E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42694000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42694000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.34E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42223000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42223000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42464000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42464000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42247000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42247000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42300000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42300000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42265000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42265000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42486000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42486000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42448000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42448000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-19</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42577000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42577000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41860000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41860000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40179000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40179000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40163000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40163000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.34E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.61</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40584000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40584000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.39E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>291.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41062000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41062000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41519000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41519000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41844000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41844000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41720000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41720000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41660000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41660000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41952000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41952000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41852000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41852000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41605000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41605000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41715000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41715000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41561000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41561000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41856000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41856000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42547000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42547000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41526000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41526000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41309000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41309000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41265000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41265000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41292000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41292000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41037000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41037000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40991000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40991000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40960000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40960000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-20</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40973000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40973000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41008000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41008000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41216000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41216000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41342000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41342000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41249000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41249000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.11</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41329000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41329000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41376000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41376000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41531000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41531000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41162000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41162000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41644000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41644000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.34E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>214</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41254000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41254000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>214</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40655000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40655000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.26E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>214</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40834000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40834000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41417000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41417000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.34E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41251000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41251000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.30E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41397000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41397000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.34E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41638000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41638000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.39E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41772000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41772000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.39E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41903000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41903000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41761000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41761000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42162000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42162000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42207000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42207000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41918000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41918000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41782000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41782000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.39E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-21</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41721000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41721000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.39E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41955000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41955000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41929000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41929000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42004000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42004000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42085000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42085000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41835000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41835000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41527000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41527000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.43E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>215</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42031000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42031000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>214</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41342000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41342000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.52E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40722000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40722000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41184000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41184000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>244.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>337.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>209</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40951000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40951000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.14E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>282.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>282.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>209</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40957000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40957000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.14E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>209</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41007000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41007000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.14E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41504000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41504000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.07E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41380000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41380000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41552000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41552000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.07E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41595000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41595000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.14E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41410000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41410000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.14E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41446000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41446000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.07E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41289000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41289000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.07E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41252000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41252000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.07E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41296000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41296000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.11</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41227000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41227000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-22</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41302000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41302000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.07E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41133000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41133000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41085000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41085000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.07E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41281000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41281000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.07E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41479000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41479000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.14E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41145000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41145000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.07E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41200000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41200000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41028000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41028000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40448000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40448000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40374000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40374000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40309000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40309000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40387000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40387000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.91E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.94E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>209.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>19.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40504000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40504000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>85.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40627000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40627000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>85.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>202</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38795000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38795000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>85.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>175</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34402000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34402000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>85.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37729000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37729000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>85.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38371000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38371000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>85.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38887000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38887000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>85.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39153000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39153000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>85.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38825000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38825000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>200.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>19.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>283.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38887000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38887000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38912000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38912000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39015000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39015000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-23</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38990000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38990000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39048000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39048000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.20E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39010000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39010000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>170</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38594000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38594000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>167</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37946000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37946000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.20E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38586000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38586000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.24E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38811000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38811000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.26E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38902000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38902000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.26E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38869000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38869000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.26E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39009000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39009000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.24E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38980000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38980000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.24E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39932000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39932000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.26E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39800000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39800000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.26E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39950000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39950000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.26E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39936000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39936000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.28E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>43378000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>43378000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>11.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.48E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>333.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>332.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48594000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48594000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.82E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>373.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>375.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49530000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49530000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.89E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>381.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49513000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49513000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.89E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49885000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49885000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.93E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>384.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>385.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>161</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48975000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48975000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.97E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>378.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>378.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49506000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49506000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49603000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49603000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>383.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49519000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49519000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.97E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>381.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-24</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49546000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49546000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49688000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49688000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>385.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>383.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49604000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49604000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>383.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49685000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49685000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>383.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>383.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49421000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49421000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>381.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>381.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49776000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49776000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>384.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>384.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49825000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49825000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>384.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>384.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49761000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49761000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>384.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>383.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49429000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49429000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.79E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.00E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>380.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>381.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>158</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49181000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49181000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.82E0</UnadjustedHourlyValue>
         <MODCCode>41</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.05E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>T</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>259.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>19.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>T</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>324.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>15.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49578000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49578000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.21E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49530000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49530000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.21E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>156</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49183000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49183000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>156</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48769000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48769000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49723000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49723000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.26E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>49815000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>49815000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.26E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>50296000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>50296000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.30E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>151</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>50843000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>50843000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>143</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>52478000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>52478000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.65E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>316.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>317.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>52548000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>52548000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.65E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>317.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>318.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>51980000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>51980000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.60E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>315.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>316.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>45777000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>45777000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48135000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48135000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.44E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>290.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42145000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42145000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.05E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>255.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>256.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-25</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42474000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42474000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.98E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>257.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>257.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42614000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42614000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.01E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>257.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42378000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42378000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.98E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>257.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>257.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42417000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42417000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.01E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>256.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42069000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42069000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.01E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>255.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>254.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41775000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41775000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.01E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>253.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>254.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41695000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41695000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.98E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>253.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>253.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>44160000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>44160000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.09E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>266.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>267.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48670000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48670000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48673000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48673000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.44E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48616000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48616000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.44E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48499000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48499000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.44E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48413000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48413000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.44E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48215000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48215000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.44E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>291.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>48295000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>48295000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.44E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>293.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>292.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>46824000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>46824000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.35E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>283.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>283.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>42135000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>42135000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.26E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>257.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>257.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>16.4</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>16</Hour>
      <OperatingTime>0.98</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38855000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38855000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.87E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>224.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>225.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40225000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40225000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.87E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>224.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>225.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40536000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40536000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.87E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>226.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>225.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>18.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40636000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40636000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.87E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>227.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>226.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40087000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40087000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.84E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>223.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>224.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39797000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39797000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.80E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>222.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39688000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39688000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.80E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>222.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-26</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39690000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39690000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.80E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39624000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39624000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.84E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>220.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39524000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39524000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.80E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>220.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>219.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>18.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39778000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39778000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.84E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>222.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>223.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39551000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39551000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.84E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39374000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39374000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.84E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>220.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>220.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39549000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39549000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.84E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>221.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>220.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39624000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39624000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.84E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>220.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>220.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>18.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36479000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36479000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.84E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>206.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>206.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33468000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33468000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.36E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>187.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>187.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30585000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30585000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>170.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>170.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31106000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31106000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>173.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>173.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30768000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30768000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>172.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>171.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30599000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30599000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>171.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>171.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30818000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30818000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>171.61</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>18.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>172.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31221000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31221000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>174.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>174.11</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31094000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31094000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.21E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>173.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>173.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>143</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31176000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31176000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>174.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>173.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>18.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>151</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32257000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32257000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>180.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>180.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>161</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32518000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32518000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.13E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>181.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>181.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>165</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33134000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33134000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.13E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>184.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>185.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>156</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33412000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33412000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>186.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>186.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>142</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31108000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31108000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.23E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>174.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>173.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>131</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29560000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29560000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.27E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>165.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>164.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-27</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>130</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29268000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29268000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.25E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>163.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>163.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>130</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29189000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29189000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.27E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>163.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>162.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>130</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29142000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29142000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.27E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>163.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>162.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>130</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29026000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29026000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.25E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>162.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>162.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>130</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29075000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29075000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.27E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>162.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>162.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>130</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28958000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28958000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.25E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>161.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>161.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>130</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28814000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28814000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.25E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>160.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>161.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>130</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28527000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28527000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.23E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>159.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>159.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>125</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28016000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28016000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.27E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>156.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>156.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>120</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27655000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27655000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.30E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>154.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>154.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>119</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27529000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27529000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>153.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>153.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>110</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26982000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26982000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>151.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>150.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>104</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26894000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26894000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>11.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.59E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>150.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>150.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>100</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26152000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26152000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>11.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.62E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>146.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>146.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>98</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>25973000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>25973000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>11.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.62E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>144.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>145.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>92</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26025000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26025000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.80E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>145.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>145.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>85</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26260000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26260000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.05E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>146.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>146.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>80</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26366000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26366000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.21E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>80</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26350000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26350000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.21E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.11</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>72</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26328000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26328000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>70</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26418000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26418000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>70</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26363000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26363000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>63</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26335000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26335000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>146.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>18.0</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>61</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26386000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26386000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-28</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>57</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26388000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26388000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>55</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26336000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26336000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>55</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26325000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26325000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>55</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26343000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26343000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>146.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>55</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26382000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26382000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>55</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26410000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26410000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>55</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26461000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26461000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>55</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26353000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26353000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>147.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>53</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26145000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26145000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>145.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>145.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>17.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>53</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26026000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26026000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.89E0</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>136.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>19.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>143.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>18.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>53</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26020000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26020000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.99E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>226.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>51</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>2</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>25962000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>25962000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.99E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>51</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>2</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26002000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26002000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.99E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>54</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26302000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26302000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.99E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>64</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26398000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26398000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.99E0</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>77</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26340000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26340000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.49E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>93</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26429000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26429000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>11.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>3.03E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>105</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26761000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26761000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.76E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>128</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>28494000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>28494000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.44E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>327.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>29149000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>29149000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.46E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>334.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>156</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33916000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33916000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.46E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>391.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>156</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34232000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34232000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.53E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>395.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>153</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33064000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33064000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.48E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>381.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33321000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33321000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.46E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>384.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-29</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33043000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33043000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.48E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>381.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32817000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32817000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.48E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>379.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32880000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32880000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.48E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>379.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32931000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32931000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.48E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>380.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33037000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33037000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.50E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>380.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33033000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33033000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.50E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>381.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>155</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33101000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33101000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.50E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>382.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>156</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33515000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33515000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.50E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>386.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34222000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34222000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.46E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>395.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34257000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34257000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>395.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>9</Hour>
      <OperatingTime>0.82</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33367000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33367000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>460.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>7.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>35821000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>35821000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>413.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34856000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34856000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>402.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33798000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33798000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>390.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33143000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33143000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>381.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32159000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32159000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>370.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32228000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32228000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>371.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>172</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>35026000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>35026000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.30E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>403.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>188</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36488000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36488000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.19E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>421.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>194</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36932000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36932000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>425.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>200</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37522000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37522000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>433.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>205</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38147000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38147000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.12E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>439.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>209</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39334000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39334000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.12E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>452.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>206</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39227000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39227000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>452.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-04-30</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>206</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38951000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38951000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>449.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>206</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38383000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38383000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>443.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>205</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38130000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38130000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>439.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>205</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38185000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38185000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>440.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>205</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37999000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37999000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>438.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>205</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38056000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38056000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>439.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>205</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38225000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38225000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>441.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>205</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38208000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38208000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>440.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>205</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38288000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38288000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>442.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>205</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38216000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38216000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>441.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>206</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38326000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38326000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>441.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>208</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38538000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38538000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>444.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>208</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38745000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38745000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>447.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>209</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38747000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38747000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>446.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38901000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38901000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>447.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39105000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39105000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>450.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39277000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39277000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.12E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>452.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39035000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39035000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>450.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38800000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38800000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>447.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38848000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38848000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.14E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>447.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39401000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39401000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>454.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39652000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39652000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>457.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39334000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39334000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>454.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39234000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39234000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>452.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-01</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39519000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39519000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>456.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39505000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39505000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>455.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39452000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39452000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>455.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39566000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39566000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>456.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39559000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39559000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>456.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39698000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39698000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>457.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39761000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39761000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>458.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39810000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39810000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>459.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39768000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39768000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.17E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>458.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39848000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39848000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>459.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>211</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39819000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39819000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>459.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>8.7</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39803000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39803000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>2.16E0</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>2.15E0</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>209.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>19.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39813000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39813000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39857000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39857000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39854000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39854000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39347000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39347000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39444000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39444000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39684000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39684000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>87.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39749000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39749000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40004000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40004000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40283000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40283000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40364000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40364000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40092000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40092000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39999000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39999000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-02</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40072000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40072000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40131000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40131000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39999000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39999000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40031000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40031000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40006000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40006000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39978000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39978000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39932000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39932000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40036000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40036000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39928000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39928000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39745000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39745000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39665000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39665000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39497000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39497000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39350000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39350000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39388000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39388000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39553000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39553000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39752000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39752000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39831000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39831000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39920000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39920000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.7</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40185000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40185000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.61</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40123000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40123000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.47E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40422000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40422000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.53E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40474000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40474000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40263000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40263000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39745000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39745000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-03</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39550000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39550000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39353000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39353000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39474000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39474000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39475000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39475000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39607000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39607000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39580000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39580000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39677000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39677000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39698000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39698000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39725000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39725000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39674000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39674000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39810000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39810000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39751000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39751000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39858000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39858000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39858000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39858000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39887000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39887000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39922000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39922000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39836000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39836000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39859000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39859000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39965000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39965000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39888000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39888000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40326000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40326000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40874000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40874000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40737000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40737000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40090000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40090000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-04</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39986000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39986000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40149000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40149000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40204000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40204000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40642000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40642000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.41E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40524000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40524000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40487000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40487000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40527000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40527000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40208000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40208000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40230000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40230000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40047000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40047000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40771000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40771000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40548000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40548000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39937000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39937000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40052000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40052000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40018000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40018000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39878000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39878000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39856000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39856000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40033000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40033000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40023000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40023000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40006000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40006000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.13E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40180000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40180000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.13E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40639000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40639000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.13E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40809000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40809000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40720000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40720000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-05</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40610000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40610000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40528000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40528000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40330000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40330000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40426000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40426000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40469000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40469000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40417000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40417000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40496000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40496000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.29E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40514000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40514000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40566000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40566000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.24E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>212</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39778000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39778000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>7.32E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>90.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>272.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>357.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>195</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36907000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36907000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>260.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>264.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.9</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>189</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36088000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36088000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>294.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>182</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34283000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34283000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.58E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>279.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>279.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>176</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33380000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33380000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.60E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>273.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>164</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32023000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32023000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>260.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>260.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31357000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31357000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31799000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31799000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>260.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>259.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31699000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31699000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>259.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31703000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31703000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.65E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31672000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31672000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.65E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>259.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31683000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31683000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.65E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>259.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>258.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31879000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31879000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>260.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>259.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32485000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32485000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.69E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>265.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>264.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32692000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32692000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.69E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>266.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>267.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-06</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32627000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32627000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.69E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>265.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>265.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32910000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32910000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.72E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>267.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32974000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32974000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32987000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32987000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32965000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32965000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33028000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33028000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33115000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33115000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33678000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33678000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.79E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33594000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33594000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.77E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33319000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33319000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>272.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33175000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33175000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32900000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32900000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>267.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33073000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33073000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32896000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32896000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32954000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32954000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32965000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32965000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33072000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33072000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33030000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33030000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32887000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32887000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>267.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33298000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33298000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.77E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33533000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33533000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.77E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>273.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>273.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33784000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33784000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33319000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33319000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33220000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33220000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-07</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33149000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33149000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33208000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33208000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33045000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33045000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32979000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32979000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.77E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33131000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33131000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.77E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33198000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33198000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.77E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33192000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33192000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.77E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33056000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33056000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.77E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33318000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33318000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33319000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33319000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.72E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33210000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33210000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.72E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32972000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32972000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.72E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>267.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33103000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33103000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.72E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.97</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33024000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33024000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.72E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>269.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>268.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33175000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33175000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.72E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33175000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33175000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33206000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33206000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33472000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33472000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>272.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>273.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33279000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33279000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.61</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33237000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33237000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33191000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33191000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>270.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33351000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33351000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>272.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>271.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33702000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33702000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33864000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33864000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-08</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33995000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33995000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>277.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>277.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33953000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33953000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>276.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>276.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34000000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34000000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>277.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>276.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33969000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33969000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>276.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>276.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33810000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33810000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33928000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33928000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>277.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>276.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33537000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33537000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>272.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33551000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33551000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.12</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>272.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33802000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33802000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.72E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33714000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33714000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>275.11</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33662000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33662000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.54E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.74E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>274.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>273.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>12.3</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33717000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33717000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.42E-1</UnadjustedHourlyValue>
         <MODCCode>41</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>T</BeginEndHourFlag>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>223.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>15.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>T</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>291.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33584000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33584000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.64E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33953000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33953000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.64E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33840000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33840000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.64E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.04</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33463000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33463000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.64E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.41</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34246000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34246000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.64E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>307.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33826000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33826000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.64E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34006000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34006000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.64E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32974000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32974000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.73E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33650000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33650000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.73E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33664000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33664000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.73E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34038000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34038000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.73E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>160</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33723000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33723000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.64E-2</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-09</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>150</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32137000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32137000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.01E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>108</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27709000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27709000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.31E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>249.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>69</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>26730000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>26730000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.59E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>240.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>27</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>2</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>25819000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>25819000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.59E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>231.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>3</Hour>
      <OperatingTime>0.43</OperatingTime>
      <HourLoad>15</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>25545000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>25545000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>20.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.59E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>228.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>4</Hour>
      <OperatingTime>0.80</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20767000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20767000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>20.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.59E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>185.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>5</Hour>
      <OperatingTime>0.12</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>21160000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>21160000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>20.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>8.62E-2</UnadjustedHourlyValue>
         <MODCCode>32</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.59E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.00</HourlyGFMReading>
         <AvgHourlySamplingRate>189.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>11.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-10</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-11</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-12</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-13</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-14</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-15</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-16</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-17</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-18</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-19</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-20</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-21</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-22</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-23</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-24</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-25</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-26</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-27</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-28</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-29</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-30</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-05-31</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-01</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-02</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-03</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-04</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-05</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-06</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-07</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-08</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-09</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-10</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-11</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-12</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-13</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-14</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-15</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-16</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-17</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-18</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-19</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-20</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-21</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-22</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>19</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>20</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>21</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>22</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-23</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>7</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>8</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>9</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>10</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>11</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>12</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>13</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>14</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>15</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>16</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>17</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>18</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>19</Hour>
      <OperatingTime>0.18</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>18469000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>18469000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>21.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.00</HourlyGFMReading>
         <AvgHourlySamplingRate>300.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.1</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.00</HourlyGFMReading>
         <AvgHourlySamplingRate>370.49</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>5.0</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>20</Hour>
      <OperatingTime>0.60</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>18409000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>18409000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>21.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>254.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>7.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>249.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>7.4</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>21</Hour>
      <OperatingTime>0.72</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>18986000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>18986000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>295.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.4</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.01</HourlyGFMReading>
         <AvgHourlySamplingRate>296.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.4</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19040000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19040000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-24</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19102000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19102000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>17404000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>17404000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>281.99</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>281.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19627000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19627000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>315.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>315.65</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20527000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20527000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.6</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>330.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>330.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue>19912000.000</AdjustedHourlyValue>
         <MODCCode>11</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>335.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio/>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>335.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio/>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue>19912000.000</AdjustedHourlyValue>
         <MODCCode>11</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>335.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio/>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>335.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio/>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue>19912000.000</AdjustedHourlyValue>
         <MODCCode>11</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>335.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio/>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>334.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio/>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue>19912000.000</AdjustedHourlyValue>
         <MODCCode>11</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>335.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio/>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>336.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio/>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>21012000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>21012000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>337.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>337.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20775000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20775000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>336.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>335.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>21154000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>21154000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>341.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>340.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>21046000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>21046000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>339.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>339.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20591000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20591000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>332.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>331.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20029000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20029000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>323.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>323.09</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20019000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20019000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>321.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>322.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20510000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20510000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>330.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>331.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20058000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20058000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>18.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>324.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>323.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19822000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19822000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>18.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>319.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>319.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19594000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19594000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>17.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>317.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>315.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19386000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19386000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>17.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>312.51</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>312.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19936000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19936000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>17.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>320.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>321.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20452000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20452000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>17.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>330.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>329.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>21008000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>21008000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>17.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>339.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>338.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>22</Hour>
      <OperatingTime>0.90</OperatingTime>
      <HourLoad>9</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>21543000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>21543000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>16.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>347.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>347.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-25</Date>
      <Hour>23</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>0</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>1</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>2</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>3</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>4</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>5</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>6</Hour>
      <OperatingTime>0.00</OperatingTime>
      <HourLoad/>
      <LoadUnitsOfMeasureCode/>
      <MATSHourLoad/>
      <LoadRange/>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>7</Hour>
      <OperatingTime>0.25</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>20165000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>20165000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>20.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.00</HourlyGFMReading>
         <AvgHourlySamplingRate>294.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.8</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.00</HourlyGFMReading>
         <AvgHourlySamplingRate>312.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19938000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19938000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>19.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>321.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>321.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19893000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19893000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>18.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>320.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>321.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19644000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19644000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>17.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>316.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>316.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>0</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19255000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19255000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>310.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>4</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19125000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19125000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>16.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>309.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>308.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>24</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>1</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>19858000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>19858000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>15.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>319.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>319.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>36</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>2</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>22755000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>22755000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>365.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>366.39</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>57</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>27760000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>27760000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>445.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>445.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>68</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31098000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31098000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>500.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>500.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>83</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31305000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31305000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.35E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>505.91</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>505.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>80</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31312000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31312000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>505.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>504.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>79</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>3</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32216000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32216000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>519.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>519.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>83</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>31377000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>31377000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>506.28</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>506.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>86</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>30641000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>30641000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>493.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>493.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>83</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32551000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32551000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>525.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>525.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-26</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>87</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32608000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32608000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>37</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>525.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>526.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>89</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32675000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32675000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>14.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.89E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>526.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>527.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>94</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33269000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33269000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.61E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>536.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>536.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>99</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34155000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34155000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.48E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>550.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>550.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>101</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34186000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34186000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.48E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>551.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>551.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>105</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>4</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34430000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34430000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.22E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>554.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>554.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>107</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>U</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34488000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34488000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>9.10E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>556.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>556.61</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>108</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>34893000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>34893000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.98E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>561.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>562.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>116</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag>D</MATSStartupShutdownFlag>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>35157000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>35157000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>13.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.75E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>567.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>566.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>123</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>35007000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>35007000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>12.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>8.03E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>564.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>564.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>130</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>5</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33634000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33634000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>11.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.34E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>543.00</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>542.63</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>133</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33336000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33336000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>11.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.18E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>537.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>537.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>134</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32956000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32956000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>11.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>7.03E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>532.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>532.27</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>139</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>32210000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>32210000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>6.69E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>518.78</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>519.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>151</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>6</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>33464000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>33464000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>10.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>6.38E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>538.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>538.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>167</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>35401000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>35401000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>6.04E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>570.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>570.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>169</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>35103000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>35103000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>566.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>565.90</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>175</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36652000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36652000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>590.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>590.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>177</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36764000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36764000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.93E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>593.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>593.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>177</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36574000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36574000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.93E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>590.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>590.20</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>178</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>35627000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>35627000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.78E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>574.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>575.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>179</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36133000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36133000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>9.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.73E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>581.55</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.03</HourlyGFMReading>
         <AvgHourlySamplingRate>582.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>184</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>7</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36694000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36694000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.69E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>592.07</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>592.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>186</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36985000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36985000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.69E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>596.60</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>596.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-27</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>187</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>36987000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>36987000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.69E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>596.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>596.81</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>189</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>37530000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>37530000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.69E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>604.67</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>604.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>192</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38131000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38131000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.69E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>615.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>615.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>193</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38231000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38231000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>616.74</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>616.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>195</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>38628000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>38628000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>623.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>623.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>197</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>39261000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>39261000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.59E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>632.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>633.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>201</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40304000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40304000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>649.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>650.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>203</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40144000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40144000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.600</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>648.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>647.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.2</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>209</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40352000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40352000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>5.35E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.8</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>5.50E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>600.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.7</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>F</BeginEndHourFlag>
         <HourlyGFMReading>0.04</HourlyGFMReading>
         <AvgHourlySamplingRate>614.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>6.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>210</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>8</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40350000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40350000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>34</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>213</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40730000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40730000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>284.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.3</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag>I</BeginEndHourFlag>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>288.22</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>14.1</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>216</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41269000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41269000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.30</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>218</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41054000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41054000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>221</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41375000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41375000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.62E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>222</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41339000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41339000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.800</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.62E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.46</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>221</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41051000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41051000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue/>
         <AdjustedHourlyValue/>
         <MODCCode>46</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue/>
         <MODCCode>38</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.18</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40972000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40972000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.80</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41042000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41042000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.96</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.57</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41060000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41060000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41421000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41421000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>88.9</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41393000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41393000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41658000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41658000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.69</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41512000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41512000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.58</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41551000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41551000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.87</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-28</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41576000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41576000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.84</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41582000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41582000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.64E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.45</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41362000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41362000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.65E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41281000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41281000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.0</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.65E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.21</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.76</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41488000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41488000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.65E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.34</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.86</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41419000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41419000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.65E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.88</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>304.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41536000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41536000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>8.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.65E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.71</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>306.13</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40844000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40844000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.900</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.63E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.94</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>220</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40418000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40418000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.700</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.60E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.68</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>221</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40200000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40200000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.58E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>222</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40596000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40596000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>222</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40453000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40453000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.10</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>223</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40134000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40134000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.1</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40274000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40274000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.19</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40333000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40333000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.53</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.26</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>225</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40430000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40430000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.48</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.42</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>226</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40542000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40542000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.54</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40698000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40698000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.11</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40510000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40510000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.37</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.95</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41045000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41045000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.82</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40645000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40645000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.56</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40505000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40505000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.2</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.73</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40931000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40931000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.31</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40708000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40708000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.38</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.43</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-29</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40771000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40771000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.92</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>0</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40788000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40788000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.52</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>1</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40826000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40826000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.02</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>2</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40601000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40601000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.06</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>299.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>3</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40999000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40999000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.62</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.59</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>4</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40902000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40902000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.64</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.35</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>5</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40773000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40773000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.3</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.29</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>6</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40821000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40821000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.32</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>7</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41104000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41104000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>303.40</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>8</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40703000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40703000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.23</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>9</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40300000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40300000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.85</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>10</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40246000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40246000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.05</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.79</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>11</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40199000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40199000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.93</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.16</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>12</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>229</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40093000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40093000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.100</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.53E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>295.14</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>13</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40399000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40399000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.4</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.77</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.36</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>14</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40340000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40340000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.200</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.55E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.83</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.47</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>15</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40349000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40349000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.66</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>16</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40318000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40318000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.72</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>296.70</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>17</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40515000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40515000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.300</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.56E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.17</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>18</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41042000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41042000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.75</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>302.01</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>19</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>41508000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>41508000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.58E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.15</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>305.33</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>20</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40816000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40816000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.44</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.03</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>21</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40915000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40915000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.89</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>301.50</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>22</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40640000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40640000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.400</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.5</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.57E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.08</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>300.24</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.5</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <HourlyOperatingData>
      <UnitID>1</UnitID>
      <Date>2024-06-30</Date>
      <Hour>23</Hour>
      <OperatingTime>1.00</OperatingTime>
      <HourLoad>228</HourLoad>
      <LoadUnitsOfMeasureCode>MW</LoadUnitsOfMeasureCode>
      <MATSHourLoad/>
      <LoadRange>9</LoadRange>
      <CommonStackLoadRange/>
      <FcFactor>1800.0</FcFactor>
      <FdFactor>9780.0</FdFactor>
      <FwFactor/>
      <FuelCode/>
      <MATSStartupShutdownFlag/>
      <MonitorHourlyValueData>
         <ParameterCode>FLOW</ParameterCode>
         <UnadjustedHourlyValue>40434000.000</UnadjustedHourlyValue>
         <AdjustedHourlyValue>40434000.000</AdjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1FL</MonitoringSystemID>
         <ComponentID>104</ComponentID>
         <PercentAvailable>99.5</PercentAvailable>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MonitorHourlyValueData>
         <ParameterCode>O2C</ParameterCode>
         <UnadjustedHourlyValue>7.500</UnadjustedHourlyValue>
         <AdjustedHourlyValue/>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1O2</MonitoringSystemID>
         <ComponentID>105</ComponentID>
         <PercentAvailable/>
         <MoistureBasis/>
      </MonitorHourlyValueData>
      <MATSMonitorHourlyValueData>
         <ParameterCode>HGC</ParameterCode>
         <UnadjustedHourlyValue>1.66E-1</UnadjustedHourlyValue>
         <MODCCode>01</MODCCode>
         <MonitoringSystemID>1HG</MonitoringSystemID>
         <ComponentID/>
         <PercentAvailable>89.6</PercentAvailable>
      </MATSMonitorHourlyValueData>
      <MATSDerivedHourlyValueData>
         <ParameterCode>HGRH</ParameterCode>
         <UnadjustedHourlyValue>1.58E-1</UnadjustedHourlyValue>
         <MODCCode>36</MODCCode>
         <FormulaIdentifier>103</FormulaIdentifier>
      </MATSDerivedHourlyValueData>
      <HourlyGFMData>
         <ComponentID>100</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>298.25</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
      <HourlyGFMData>
         <ComponentID>101</ComponentID>
         <BeginEndHourFlag/>
         <HourlyGFMReading>0.02</HourlyGFMReading>
         <AvgHourlySamplingRate>297.98</AvgHourlySamplingRate>
         <SamplingRateUOM>CCMIN</SamplingRateUOM>
         <HourlySFSRRatio>13.6</HourlySFSRRatio>
      </HourlyGFMData>
   </HourlyOperatingData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-01</BeginDate>
      <BeginHour>10</BeginHour>
      <EndDate>2024-04-04</EndDate>
      <EndHour>9</EndHour>
      <HgSystemConcentration/>
      <PairedTrapAgreement/>
      <AbsoluteDifferenceIndicator/>
      <MODCCode>34</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL682988</SorbentTrapSN>
         <MainTrapHg>7.63E-1</MainTrapHg>
         <BTTrapHg>8.00E-4</BTTrapHg>
         <SpikeTrapHg>1.53E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.5400</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>14.1</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>FAILED</SamplingRatioCheckResultCode>
         <HgConcentration>1.41E0</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.1</PercentBreakthrough>
         <PercentSpikeRecovery>95.6</PercentSpikeRecovery>
         <TrainQAStatusCode>FAILED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL682952</SorbentTrapSN>
         <MainTrapHg>9.57E-1</MainTrapHg>
         <BTTrapHg>0.00E0</BTTrapHg>
         <SpikeTrapHg>1.41E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.6200</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>14.1</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>FAILED</SamplingRatioCheckResultCode>
         <HgConcentration>1.54E0</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>88.1</PercentSpikeRecovery>
         <TrainQAStatusCode>FAILED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-04</BeginDate>
      <BeginHour>9</BeginHour>
      <EndDate>2024-04-08</EndDate>
      <EndHour>8</EndHour>
      <HgSystemConcentration>2.08E-1</HgSystemConcentration>
      <PairedTrapAgreement>0.96</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL682995</SorbentTrapSN>
         <MainTrapHg>2.28E-1</MainTrapHg>
         <BTTrapHg>5.00E-4</BTTrapHg>
         <SpikeTrapHg>1.60E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.1100</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.8</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>2.06E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.2</PercentBreakthrough>
         <PercentSpikeRecovery>100.0</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL682903</SorbentTrapSN>
         <MainTrapHg>2.89E-1</MainTrapHg>
         <BTTrapHg>1.40E-3</BTTrapHg>
         <SpikeTrapHg>1.57E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.3800</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.8</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>2.10E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.5</PercentBreakthrough>
         <PercentSpikeRecovery>98.1</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-08</BeginDate>
      <BeginHour>9</BeginHour>
      <EndDate>2024-04-11</EndDate>
      <EndHour>8</EndHour>
      <HgSystemConcentration>2.32E-1</HgSystemConcentration>
      <PairedTrapAgreement>0.86</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL689568</SorbentTrapSN>
         <MainTrapHg>1.86E-1</MainTrapHg>
         <BTTrapHg>5.00E-4</BTTrapHg>
         <SpikeTrapHg>1.56E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.8100</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>14.2</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>2.30E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.3</PercentBreakthrough>
         <PercentSpikeRecovery>97.5</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL689547</SorbentTrapSN>
         <MainTrapHg>2.35E-1</MainTrapHg>
         <BTTrapHg>1.10E-3</BTTrapHg>
         <SpikeTrapHg>1.55E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.0100</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>14.2</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>2.34E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.5</PercentBreakthrough>
         <PercentSpikeRecovery>96.9</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-11</BeginDate>
      <BeginHour>9</BeginHour>
      <EndDate>2024-04-15</EndDate>
      <EndHour>9</EndHour>
      <HgSystemConcentration>4.54E-1</HgSystemConcentration>
      <PairedTrapAgreement>0.33</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL689590</SorbentTrapSN>
         <MainTrapHg>5.28E-1</MainTrapHg>
         <BTTrapHg>1.30E-3</BTTrapHg>
         <SpikeTrapHg>1.55E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.1700</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.6</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>4.52E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.2</PercentBreakthrough>
         <PercentSpikeRecovery>96.9</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL689629</SorbentTrapSN>
         <MainTrapHg>6.69E-1</MainTrapHg>
         <BTTrapHg>0.00E0</BTTrapHg>
         <SpikeTrapHg>1.61E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.4700</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.7</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>4.55E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>100.6</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-15</BeginDate>
      <BeginHour>9</BeginHour>
      <EndDate>2024-04-18</EndDate>
      <EndHour>8</EndHour>
      <HgSystemConcentration>5.74E-1</HgSystemConcentration>
      <PairedTrapAgreement>1.39</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL689675</SorbentTrapSN>
         <MainTrapHg>5.05E-1</MainTrapHg>
         <BTTrapHg>1.00E-3</BTTrapHg>
         <SpikeTrapHg>1.58E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.8700</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.9</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>5.82E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.2</PercentBreakthrough>
         <PercentSpikeRecovery>98.8</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL689658</SorbentTrapSN>
         <MainTrapHg>6.17E-1</MainTrapHg>
         <BTTrapHg>0.00E0</BTTrapHg>
         <SpikeTrapHg>1.57E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.0900</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>14.0</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>5.66E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>98.1</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-18</BeginDate>
      <BeginHour>9</BeginHour>
      <EndDate>2024-04-22</EndDate>
      <EndHour>9</EndHour>
      <HgSystemConcentration>5.32E-1</HgSystemConcentration>
      <PairedTrapAgreement>1.41</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL684843</SorbentTrapSN>
         <MainTrapHg>6.19E-1</MainTrapHg>
         <BTTrapHg>9.00E-4</BTTrapHg>
         <SpikeTrapHg>1.60E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.1500</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.9</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>5.39E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.1</PercentBreakthrough>
         <PercentSpikeRecovery>100.0</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL684814</SorbentTrapSN>
         <MainTrapHg>7.59E-1</MainTrapHg>
         <BTTrapHg>6.00E-4</BTTrapHg>
         <SpikeTrapHg>1.60E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.4500</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.9</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>5.24E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.1</PercentBreakthrough>
         <PercentSpikeRecovery>100.0</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-22</BeginDate>
      <BeginHour>10</BeginHour>
      <EndDate>2024-04-23</EndDate>
      <EndHour>10</EndHour>
      <HgSystemConcentration>7.91E-1</HgSystemConcentration>
      <PairedTrapAgreement>1.71</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL697830</SorbentTrapSN>
         <MainTrapHg>2.41E-1</MainTrapHg>
         <BTTrapHg>1.00E-4</BTTrapHg>
         <SpikeTrapHg>1.60E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.3000</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.6</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>8.04E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>100.0</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL697911</SorbentTrapSN>
         <MainTrapHg>2.87E-1</MainTrapHg>
         <BTTrapHg>5.00E-4</BTTrapHg>
         <SpikeTrapHg>1.50E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.3700</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.6</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>7.77E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.2</PercentBreakthrough>
         <PercentSpikeRecovery>93.8</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-23</BeginDate>
      <BeginHour>19</BeginHour>
      <EndDate>2024-04-25</EndDate>
      <EndHour>8</EndHour>
      <HgSystemConcentration>1.79E0</HgSystemConcentration>
      <PairedTrapAgreement>1.40</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL721272</SorbentTrapSN>
         <MainTrapHg>9.41E-1</MainTrapHg>
         <BTTrapHg>8.00E-4</BTTrapHg>
         <SpikeTrapHg>1.51E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.5200</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.0</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>1.81E0</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.1</PercentBreakthrough>
         <PercentSpikeRecovery>94.4</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL721261</SorbentTrapSN>
         <MainTrapHg>1.18E0</MainTrapHg>
         <BTTrapHg>0.00E0</BTTrapHg>
         <SpikeTrapHg>1.43E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.6700</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.0</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>1.76E0</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>89.4</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-25</BeginDate>
      <BeginHour>8</BeginHour>
      <EndDate>2024-04-29</EndDate>
      <EndHour>8</EndHour>
      <HgSystemConcentration>1.89E0</HgSystemConcentration>
      <PairedTrapAgreement>0.80</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL697793</SorbentTrapSN>
         <MainTrapHg>1.44E0</MainTrapHg>
         <BTTrapHg>2.00E-4</BTTrapHg>
         <SpikeTrapHg>1.56E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.7600</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>16.5</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>1.90E0</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>97.5</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL697848</SorbentTrapSN>
         <MainTrapHg>1.83E0</MainTrapHg>
         <BTTrapHg>1.00E-3</BTTrapHg>
         <SpikeTrapHg>1.55E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.9800</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>16.5</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>1.87E0</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.1</PercentBreakthrough>
         <PercentSpikeRecovery>96.9</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-04-29</BeginDate>
      <BeginHour>9</BeginHour>
      <EndDate>2024-05-02</EndDate>
      <EndHour>10</EndHour>
      <HgSystemConcentration>2.16E0</HgSystemConcentration>
      <PairedTrapAgreement/>
      <AbsoluteDifferenceIndicator/>
      <MODCCode>32</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL697908</SorbentTrapSN>
         <MainTrapHg>2.50E0</MainTrapHg>
         <BTTrapHg>9.00E-4</BTTrapHg>
         <SpikeTrapHg>1.55E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.2900</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>8.7</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>1.94E0</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>96.9</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL697805</SorbentTrapSN>
         <MainTrapHg>2.84E0</MainTrapHg>
         <BTTrapHg>7.00E-4</BTTrapHg>
         <SpikeTrapHg>1.64E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.4100</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>8.6</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>FAILED</SamplingRatioCheckResultCode>
         <HgConcentration>2.01E0</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>102.5</PercentSpikeRecovery>
         <TrainQAStatusCode>FAILED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-05-02</BeginDate>
      <BeginHour>17</BeginHour>
      <EndDate>2024-05-06</EndDate>
      <EndHour>8</EndHour>
      <HgSystemConcentration>7.32E-1</HgSystemConcentration>
      <PairedTrapAgreement>2.60</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL736716</SorbentTrapSN>
         <MainTrapHg>8.56E-1</MainTrapHg>
         <BTTrapHg>0.00E0</BTTrapHg>
         <SpikeTrapHg>1.67E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.1400</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.2</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>7.51E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>104.4</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL736686</SorbentTrapSN>
         <MainTrapHg>1.02E0</MainTrapHg>
         <BTTrapHg>3.00E-4</BTTrapHg>
         <SpikeTrapHg>1.66E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.4300</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.3</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>7.13E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>103.8</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-05-06</BeginDate>
      <BeginHour>9</BeginHour>
      <EndDate>2024-05-09</EndDate>
      <EndHour>10</EndHour>
      <HgSystemConcentration>1.54E-1</HgSystemConcentration>
      <PairedTrapAgreement>0.00</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL697902</SorbentTrapSN>
         <MainTrapHg>1.22E-1</MainTrapHg>
         <BTTrapHg>8.00E-4</BTTrapHg>
         <SpikeTrapHg>1.49E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.8000</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>12.3</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>1.54E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.7</PercentBreakthrough>
         <PercentSpikeRecovery>93.1</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL697766</SorbentTrapSN>
         <MainTrapHg>1.52E-1</MainTrapHg>
         <BTTrapHg>3.00E-4</BTTrapHg>
         <SpikeTrapHg>1.58E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.9900</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>12.2</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>1.54E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.2</PercentBreakthrough>
         <PercentSpikeRecovery>98.8</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-05-09</BeginDate>
      <BeginHour>10</BeginHour>
      <EndDate>2024-05-10</EndDate>
      <EndHour>5</EndHour>
      <HgSystemConcentration>8.62E-2</HgSystemConcentration>
      <PairedTrapAgreement/>
      <AbsoluteDifferenceIndicator/>
      <MODCCode>32</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL697775</SorbentTrapSN>
         <MainTrapHg>2.55E-2</MainTrapHg>
         <BTTrapHg>1.00E-4</BTTrapHg>
         <SpikeTrapHg>1.63E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.3300</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>11.2</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>7.76E-2</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.4</PercentBreakthrough>
         <PercentSpikeRecovery>101.9</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL697957R</SorbentTrapSN>
         <MainTrapHg>3.38E-2</MainTrapHg>
         <BTTrapHg>0.00E0</BTTrapHg>
         <SpikeTrapHg>1.28E-1</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.4100</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>11.2</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>8.24E-2</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>8.0</PercentSpikeRecovery>
         <TrainQAStatusCode>FAILED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-06-24</BeginDate>
      <BeginHour>19</BeginHour>
      <EndDate>2024-06-28</EndDate>
      <EndHour>7</EndHour>
      <HgSystemConcentration>5.35E-1</HgSystemConcentration>
      <PairedTrapAgreement>0.09</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL736573</SorbentTrapSN>
         <MainTrapHg>8.06E-1</MainTrapHg>
         <BTTrapHg>2.50E-3</BTTrapHg>
         <SpikeTrapHg>1.61E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.5100</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>7.4</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>5.35E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.3</PercentBreakthrough>
         <PercentSpikeRecovery>100.6</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL736505</SorbentTrapSN>
         <MainTrapHg>9.55E-1</MainTrapHg>
         <BTTrapHg>9.00E-4</BTTrapHg>
         <SpikeTrapHg>1.60E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.7900</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>7.6</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>5.34E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.1</PercentBreakthrough>
         <PercentSpikeRecovery>100.0</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
   <SorbentTrapData>
      <UnitID>1</UnitID>
      <MonitoringSystemID>1HG</MonitoringSystemID>
      <BeginDate>2024-06-28</BeginDate>
      <BeginHour>9</BeginHour>
      <EndDate>2024-07-01</EndDate>
      <EndHour>10</EndHour>
      <HgSystemConcentration>1.66E-1</HgSystemConcentration>
      <PairedTrapAgreement>1.51</PairedTrapAgreement>
      <AbsoluteDifferenceIndicator>0</AbsoluteDifferenceIndicator>
      <MODCCode>01</MODCCode>
      <RATAIndicator>0</RATAIndicator>
      <APSCode/>
      <SamplingTrainData>
         <ComponentID>100</ComponentID>
         <SorbentTrapSN>OL721322</SorbentTrapSN>
         <MainTrapHg>1.45E-1</MainTrapHg>
         <BTTrapHg>0.00E0</BTTrapHg>
         <SpikeTrapHg>1.61E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>0.8900</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.6</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>1.63E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.0</PercentBreakthrough>
         <PercentSpikeRecovery>100.6</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
      <SamplingTrainData>
         <ComponentID>101</ComponentID>
         <SorbentTrapSN>OL721307</SorbentTrapSN>
         <MainTrapHg>1.84E-1</MainTrapHg>
         <BTTrapHg>1.10E-3</BTTrapHg>
         <SpikeTrapHg>1.60E0</SpikeTrapHg>
         <SpikeReferenceValue>1.60E0</SpikeReferenceValue>
         <TotalSampleVolumeDSCM>1.1000</TotalSampleVolumeDSCM>
         <ReferenceSFSRRatio>13.6</ReferenceSFSRRatio>
         <SamplingRatioCheckResultCode>PASSED</SamplingRatioCheckResultCode>
         <HgConcentration>1.68E-1</HgConcentration>
         <PostLeakCheckResultCode>PASSED</PostLeakCheckResultCode>
         <PercentBreakthrough>0.6</PercentBreakthrough>
         <PercentSpikeRecovery>100.0</PercentSpikeRecovery>
         <TrainQAStatusCode>PASSED</TrainQAStatusCode>
         <SampleDamageExplanation/>
      </SamplingTrainData>
   </SorbentTrapData>
</Emissions>